Eaton PDU

  • Part: 2330384
  • Model: EVMAGU23X-E
$3,763.00

Availability

Out of Stock

Rated for any rack IT infrastructure

With its universal input, versatile C39 outlets and global approval, Eaton's G4 universal input rack PDU (G4 UPDU) is a single solution equipped to meet the most diverse data center rack power needs. With basic, metered input and managed models available, this PDU accommodates single- and three-phase power in 208V and 415/240V environments, as well as equipment with a variety of connectors and power demands. The G4 UPDU includes all the sophisticated management capabilities you expect from an Eaton PDU and can easily be deployed into a single data center or a global project across multiple locations-saving time, reducing costs and simplifying

power management. Power almost any equipment, anywhere Universal input

The G4 UPDU has power ratings from 5 kW up to 23 kW and single- or three-phase power options. It can be paired with any one of 17 removable input cables with 15 different plugs. By accommodating rack equipment with a broad range of power needs, it alleviates the cost and complexity of mixing and matching different PDUs for different installations and helps ensure you don't outgrow your PDU as powerneeds evolve.

Outlets that give you options

C39 outlets on the G4 UPDU allow both C14 and C20 plugs, adding flexibility to deployments and reducing the quantity of PDUs you will need to purchase and install.

Global approval

The G4 UPDU meets standards used all over the world, so you can source a single PDU chassis globally and pair it with cables rated for the voltage requirements at each destination.

Enhanced security

Managed and metered input G4 UPDU models include a user- configurable firewall. Their embedded, hot-swappable gigabit network module (GNM) offers market-leading cybersecurity capabilities, including zero-trust architecture and zero-touch provisioning that facilitates security updates and reduces human error.

Maximize control | Outlet-level management boosts performance and efficiency

The G4 UPDU offers options for metering, monitoring and switching at the outlet level for granular power data and precise management of power delivery. This oversight lets you prioritize loads and control inrush through power-on sequencing. It also lets you remotely power cycle unresponsive equipment and power off unused outlets to prevent the PDU from powering unauthorized equipment.The G4 UPDU's outlet-level alerts and remote control will help you respond faster to power issues and improve uptime, especially in remote and/or lightly staffed facilities

Simplify installation | Small footprint saves space for revenue-generating equipment

The G4 UPDU has 24- and 42-outlet models. It includes end-entry input options and evenly distributed outlets along its 42U chassis. Its low-profile circuit breakers are flush with the chassis and its narrow, single-wide(2 in.) width provides multiple mounting options. The G4 UPDU and attached cabling are designed to cohabit as seamlessly as possible with other rack equipment.

Painless box-to-rack experience

The G4 UPDU's toolless mounting buttons offer multiple mounting options to fit your rack's layout and power needs. It can be mounted front- or side-facing by simply moving the mounting buttons. Itshot-swappable GNM can be removed without interrupting power. You can cascade up to 40 units with individual IP addresses, simplifying management and cutting costs.

  • General Information
    • Manufacturer
    • Eaton Corporation
    • Manufacturer Website Address
    • http://www.eatoncorp.com.au
    • Brand Name
    • Eaton
    • Product Series
    • G4
    • Product Type
    • PDU

  • Technical Information
    • PDU Type
    • Managed
    • Plug/Connector Type
    • Universal Input
    • Receptacle Type
    • IEC 60320 C13
    • IEC 60320 C39
    • Receptacle Detail
    • 24 x IEC 60320 C13
    • 18 x IEC 60320 C39
  • Power Description
    • Power Rating (Watt)
    • 23 kW
    • Input Current
    • 55 A
  • Interfaces/Ports
    • Network (RJ-45)
    • Yes
  • Physical Characteristics
    • Mounting Orientation
    • Vertical
    • Mount Type
    • Rack-mountable
    • Form Factor
    • Vertical
    • Rack Height
    • 0U
    • Height
    • 1828.8 mm
    • Width
    • 53.3 mm
    • Depth
    • 66 mm